Duct Lagging

Duct Lagging

Duct Lagging is typically used to wrap noisy pipes and ducts, and thus help to block the noise contents moving through he pipes. From air flow to liquid content, duct lagging helps to increase sound absorption in the cavity and provides thermal insulation as well.

Types of duct lagging that include a foil-faced reinforced exterior will readily accept a matching lag tape for easy installation. The foil-face also serves as a protective jacket for indoor or outdoor applications. The 2# per sq. foot barrier and the 2″ thick quilted quilted fiberglass absorber improves overall acoustical performance, especially at low frequencies.

Download Product Brochure

1B Lag

Reinforced Foil-Faced Vinyl Barrier

PDF Spec Sheets: 1B Duct Lagging

duct lagging 1b lag

Product Data

  • 1 Pound Per Square Foot Reinforced Foil-Faced Vinyl Barrier
  • Nominal Thickness: .090″
  • Standard Roll: 48″W x 30'L
  • Weight: 1.0 lb. psf
  • Temperature Range: -10° to +180° F
  • Flammability: UL 94 meets VO FMVSS 302: Pass
  • Easy to cut, wrap and install with matching lag tape

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
Product125 Octave Band Frequencies (Hz)
ASTM E-90 & E 413
250
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
500
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
1K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
2K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
4K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
STC
Product1B Lag Octave Band Frequencies (Hz)
ASTM E-90 & E 413
15
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
16
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
21
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
26
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
33
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
38
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
26
*The data presented in this table is provided for informational purposes only.

1B QA-3

Reinforced Foil-Faced Vinyl Barrier Bonded to 1” Scrim Faced Quilted Fiberglass

PDF Spec Sheets: 1B QA-3 Duct Lagging

duct lagging 1b lag qa3

Product Data

  • 1 Pound Per Square Foot
  • Nominal Thickness: 1.0″
  • Standard Roll: 48″W x 30'L
  • Weight: 1.2 lb. psf
  • Temperature Range: -20° to +350° F
  • “R” Factor: 4.0
  • Flammability - Class A (or 1) Per ASTM E84
  • Flammability / Smoke Density: 19.5
  • Flammability / Flame Spread: 12.5
  • Easy to cut, wrap and install with matching lag tape

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
Product125 Octave Band Frequencies (Hz)
ASTM E-90 & E 413
250
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
500
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
1K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
2K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
4K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
8K
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
STC
Product1B QA-3 Octave Band Frequencies (Hz)
ASTM E-90 & E 413
18
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
18
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
23
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
30
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
39
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
46
Octave Band Frequencies (Hz)
ASTM E-90 & E 413
29
*The data presented in this table is provided for informational purposes only.

1B QA-9

Reinforced Foil-Faced Vinyl Barrier Bonded to 2” Scrim Faced Quilted Fiberglass

PDF Spec Sheets: 1B QA-9 Duct Lagging

duct lagging 1b lag qa3

Product Data

  • 1 Pound Per Square Foot
  • Nominal Thickness: 2.0″
  • Standard Roll: 48″W x 30'L
  • Weight: 1.4 lb. psf
  • Temperature Range: -20° to +200° F
  • “R” Factor: 8.0
  • Flammability - Class A (or 1) Per ASTM E84
  • Flammability / Smoke Density: 19.5
  • Flammability / Flame Spread: 12.5
  • Easy to cut, wrap and install with matching lag tape

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
125125 250250 500500 1K1K 2K2K 4K4K STCSTC
1251B QA-9 25019 50020 1K23 2K33 4K44 STCOctave Band Frequencies (Hz)
ASTM E-90 & E 413
53
30
*The data presented in this table is provided for informational purposes only.

2B LAG

Reinforced Mylar-Faced Vinyl Barrier

PDF Spec Sheets: 2B Duct Lagging

duct lagging 2b lag

Product Data

  • 1 Pound Per Square Foot
  • Nominal Thickness: 1.0″
  • Standard Roll: 48″W x 30’L
  • Weight: 2.2 lb. psf
  • Temperature Range: -20° to +350° F
  • “R” Factor: 4.0
  • Flammability – Class A (or 1) Per ASTM E84
  • Flammability / Smoke Density: 19.5
  • Flammability / Flame Spread: 12.5
  • Easy to cut, wrap and install with matching lag tape

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
125125 250250 500500 1K1K 2K2K 4K4K STCSTC
1252B QA-3 25020 50023 1K28 2K37 4K48 STCOctave Band Frequencies (Hz)
ASTM E-90 & E 413
56
32
*The data presented in this table is provided for informational purposes only.

2B QA-3

Reinforced Foil-Faced Vinyl Barrier Bonded to 1” Thick Quilted Fiberglass Absorber

PDF Spec Sheets: 2B QA-3 Duct Lagging

duct lagging 2b lag qa3-9

Product Data

  • 2 Pound Per Square Foot
  • Nominal Thickness: 1.0″
  • Standard Roll: 48″W x 30’L
  • Weight: 2.2 lb. psf
  • Temperature Range: -20° to +350° F
  • “R” Factor: 4.0
  • Flammability – Class A (or 1) Per ASTM E84
  • Flammability / Smoke Density: 19.5
  • Flammability / Flame Spread: 12.5
  • Easy to cut, wrap and install with matching lag tape

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
125125 250250 500500 1K1K 2K2K 4K4K STCSTC
1252B QA-3 25020 50023 1K28 2K37 4K48 STCOctave Band Frequencies (Hz)
ASTM E-90 & E 413
56
32
*The data presented in this table is provided for informational purposes only.

2B QA-9

Reinforced Foil-Faced Vinyl Barrier Bonded to 2” Scrim Faced Quilted Fiberglass

PDF Spec Sheets: 2B QA-9 Duct Lagging

duct lagging 2b lag qa3-9

Product Data

  • 2 Pound Per Square Foot
  • Nominal Thickness: 2.0″
  • Standard Roll: 48″W x 30'L
  • Weight: 2.4 lb. psf
  • Temperature Range: -20° to +200° F
  • “R” Factor: 9.0Flammability - Class A (or 1) Per ASTM E84
  • Flammability / Smoke Density: 19.5
  • Flammability / Flame Spread: 12.5
  • Easy to cut, wrap and install with matching lag tape
  • 100% adhesion between barrier and quilt

Acoustical Data

Sound Transmission Loss (dB) Octave & Center Frequencies

Product Octave Band Frequencies (Hz)
ASTM E-90 & E 413
125125 250250 500500 1K1K 2K2K 4K4K STCSTC
1252B QA-9 25021 50024 1K30 2K41 4K54 STCOctave Band Frequencies (Hz)
ASTM E-90 & E 413
58
34
*The data presented in this table is provided for informational purposes only.

Want to talk to someone about your project?

Contact us